Product Category
Current Location:Home > Product Details>MSO5054F(G)Product Details

MSO5054F(G)

4 Channel Oscilloscope;
8 Channel Logic Analyzer;
25MHz Arb.Waveform Generator;
Large 7 inch 64K color Display, WVGA: 800*480.

Feature

  • 4 Channel Oscilloscope+8 Channel Logic Analyzer + 25MHz Arb. Waveform Generator(MSO5074FG).
  • Abundant Trigger type: Video, Edge, Slope, Pluse Width, Overtime, Alternative, Code-type, Duration, Queue, Repeat trigger.
  • Large 7 inch 64K color Display, WVGA: 800*480.
  • USB host and device connectivity, standard.
  • Ultrathin desigh, handy volume, easily portable.

Oscilloscope

  • 1Gsa/s Real Sample Rate;
  • 4 Channels Oscilloscope;
  • 40MHz Bandwidth, 1MRecord Length;
  • 32 automotive measurement and FFT Analysis for Simplified Waveform Abalysis.

Logic Analyzer

  • 8 Channles Logic Analyzer;
  • 500MHz Sample Rate
  • 1MRecord Length

Arb. Waveform Generator

  • 25MHz Arb. Waveform Generator Output(Sine wave up to 75MHz)
  • 200MSa/s Sample Rate;
  • 12bit Pattern Generator
  • 50MHz Frenquery Counter

Function Picture


This device is running Linux , for more detail see

Model MSO5054FG MSO5054F
Acquisition
Sample Rate Real-Time Sample: 1GS/s
Acquisition Modes
Normal Normal data only
Peak Detect High-frequency and randon glith capture
Average Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling AC, DC, GND
Inpits Impendance 1MΩ±2% 20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above
Horizontal
Sample Rate Range 1GS/s
Waveform Interpolation (sin x)/x
Record Length 1M
SEC/DIV Range 4ns/div to 40s/div, in a  2, 4, 8 sequence,
Sample Rate and
Delay Time Accuracy
±50ppmat over any ≥1ms time interval)
Position Range 20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s;
Delta Time Measurement Accuracy
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Position Range 2mV/div to 200mV/div, ±2V
200mV/div to 5V/div, ±50V
Bandwidth 40MHz;
Rise Time at BNC( typical) 8.8ns;
Analog Bandwidth in
Normal and Average
modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, ±400mV
50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V
5V/div, ±50V
Math +, -, *, /, FFT
FFT Windows HanningFlatopRectamgularBartlettBlackman; 1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) 10Hz at BNC
DC Gain Accuracy ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode
When vertical displacement is zero, and N 16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and N
16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for s
Volts Measurement Repeatability,
Average Acquisition Mode
Delta volts between any two averages of 16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2, CH3, CH4): 1div from DC to 10MHz;1.5div from 10MHz to Full;
DC(EXT): 200mV from DC to Full;
DC(EXT/5):1V from DC to Full;  
AC: Attenuates signals below 10Hz   
HF Reject: Attenuates signals above 80kHz
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range CH1, CH2, CH3, CH4: ±8 divisions from center of screen;
EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns CH1, CH2, CH3, CH4: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) Operates with input signals 50Hz
Video Trigger
Video Trigger Type  CH1, CH2, CH3, CH4: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger when (< , >, = , or ); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Slope Trigger
Slope Trigger Mode Trigger when (< , > , = , or ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger
Over Time Mode Rising edge or Falling edge
Time Range 20ns ~ 10s
Alternative Trigger
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measurement
Cursor Measurement Manual: Voltage difference between cursors: V
             Time difference between cursors:
T
             Reciprocal of
T in Hertz (1/ΔT);
Tracing: The valtage and time at a waveform point;
Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF
Display
Display Type 7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution 800 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Logic Analyzer Specifications
Channels 8 Channels
Max. Input Impendence 200K(C=10p)
Input Voltage Range 0V~3V
Logic Threshold Range 0V~3V
Max. Sample Rate 500MHz
 Compatible Input TTL, CMOS, ECL
Sample Depth 1M
Trigger
Edge Trigger D0-D7 select slope (rising or falling edge)
Pulse Width D0-D7 select pulse polarity (positive or negative pulse), trigger when (=, , >, <), trigger pulse width
Code-type D0-D7 select code-type (H, L, X)
Duration D0-D7 select persist time and trigger when (data terminate, data start, and data delay)
Queue D0-D7 select specific data index (0-3) and code-type (H, L, X)
Repeat D0-D7 select code-type (H, L, X) and repeat times
Arb. Waveform Generator Specifications (MSO5054FG)
Wave frequency DC~25MHz
DAC clock 2K~200MHz adjustable
Waveform Length 4KSa
Vertical Resolution 12 bit
Frequency stabilization <30ppm
Amplitude ±3.5V Max.
Output impedance 50 Ω
Output  current 50mA Ipeak=50mA
System Bandwidth 25M
Wave distortion -50dBc(1KHz),  -40dBc(10KHz)
Frequency area DC~50MHz
Input Amplitude   400mVpp~18Vpp
Coupling DC
Frequency precision ±Time Base Error ±1 Count
input impedance > 100KΩ
Pattern Generator 12Bit
Probe Compensator Output
Output Voltage( typical) About 5Vpp into 1MΩ load
Frequency(typical) 1kHz
General Features
Supply Voltage 100-120VACRMS(±10%), 45Hz to 440Hz, CAT
120-240VACRMS(±10%), 45Hz to 66Hz, CAT
Power Consumption <30W
Fuse 2A, T rating, 250V
Temperature Operating: 32 to 122 (0 to 50);
Nonoperating: -40
to 159.8 (-40 to +71)
Cooling Method Convection
Humidity +104 or below (+40 or below): ≤90% relative humidity;
106
to 122 (+41 to 50): ≤60% relative humidity
Altitude Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)
Size Length 385mm; Width 200mm; Height 245mm
Weight 3.5KG(with Packing);  2.08KG(without Packing

   
   
   
   
   

NumberAttachments TitleOperating
1MSO5054F(G) ManualDownload
2MSO5054F(G) DriverDownload
3MSO5054F(G) SoftwareDownload
4MSO5074F(G) ManualDownload
5MSO5074F(G) Driver Download
6MSO5074F(G) SoftwareDownload

Copyright (c) 2006 hantek.com.cn All rights reserved