Hantek2000 Series
Great function with small size!
Minimalist keyboard design simplify operation, easy to use.
Oscilloscope + Waveform
Generator + Multimeter:
Multi-purpose station own three universal test instrument functions. Outgoing right-hand product for engineers.
Waveform Generator Function
A multipurpose instrument that helps complete your tasks more quickly, improves work
efficiency, and meets all your current and future test needs.
Multifunction Digital Multimeter Function
High sensitivity and accuracy, showing clear, stronganti-overload capability, easy to carry.
Intelligent Charging Control
Be able to recharged by 5V/2A large current or ordinary computer USB port, measurement can be done even while charging, convenience and user-friendly.
Large-capacity Lithium Battery + Ultra Low Power + Type C
Data Transfer/Charging Interface
18650 replaceable lithium battery power system, free from replace battery;
Be able to recharged by 5V/2A large current or ordinary computer USB port,allow while charging,
while using, very convenient and handy;
Type C charging interface, after every recharge of 2 hours, the device can be used continuously for
a full day or standby more than two months;
Type C power + data transfer interface, can share the charger and data cable with your mobile phone;
Suspended Support, Multiangular Adjusting, Let
you Enjoy Convenience
Function Review
Connectors Review
Interface Review
Powerful PC software
Oscilloscope powerful functions: 20 kinds of automatic measurement, cursor measurement,
waveform printing and saving functions, REF and Math functions, Pass / Fail functions.
The waveform generator is able to draw and output arbitrary waveforms on its PC software
Its multimeter with recorder function, which support the measurement resultsto nerate the curves
and analyze them.
Accessories
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Specification
Model | Hantek2D72 | Hantek2D42 | Hantek2C72 | Hantek2C42 |
Oscilloscope Mode | ||||
Bandwidth | 70MHz | 40MHz | 70MHz | 40MHz |
Channel | 2CH+DMM+AWG | 2CH+DMM+AWG | 2CH+DMM | 2CH+DMM |
Horizontal | ||||
Sample Rate Range | 250MSa/s(Single-channel), 125MSa/s(Dual-channel) | |||
Waveform Interpolation | (sin x)/x | |||
Record Length | Max. 6K for single-channel; 3K samples per dual-channel | |||
SEC/DIV Range | 5ns/div~500s/div 1, 2, 5 sequence | |||
Vertical | ||||
A/D Converter | 8-bit resolution,each channel sampled simultaneously | |||
VOLTS/DIV Range | 10mV/div~10V/divat input BNC | |||
Bandwidth Limit, typical | 20MHz | |||
Low Frequency Response (-3db) | ≤10Hz at BNC | |||
Rise Time at BNC, typical | ≤5ns | |||
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div | |||
Note: Bandwidth reduced to 6MHz when using a 1X probe. | ||||
Acquisition | ||||
Acquisition Modes | Normal | |||
Trigger | ||||
Type | Edge | |||
Mode | Auto, Normal, single | |||
Level | ±4 divisions from center of screen | |||
Trigger Level Accuracy | 0.2div × volts/div within ±4 divisions from center of screen | |||
Slope | Rising, Falling, Rising & Falling | |||
Source | CH1/CH2 | |||
Input | ||||
Coupling | DC, AC or GND | |||
Input Impedance, | 25pF±3 pF, 1MΩ±2% | |||
DC coupled | ||||
Probe Attenuation | 1X, 10X | |||
Supported Probe Attenuation Factors | 1X, 10X, 100X, 1000X | |||
Maximum Input Voltage | 150VRMS | |||
Measurement | ||||
Cursor | Voltage difference between cursors: △V | |||
Time difference between cursors: △T | ||||
Automatic Measurements | Frequency, Amplitude | |||
Arbitrary Waveform Generator Mode | ||||
Waveform Frequency | Sine: 1Hz~25MHz | - | - | |
Square: 1Hz~10MHz | - | - | ||
Ramp: 1Hz~1MHz | - | - | ||
EXP: 1Hz~5MHz | - | - | ||
Sampling | 250MSa/s | - | - | |
Amplitude | 2.5Vpp(50Ω) | - | - | |
5Vpp(High impedance) | - | - | ||
Frequency Resolution | 0.10% | - | - | |
Channel | 1CH waveform output | - | - | |
Waveform Depth | 512Sa | - | - | |
Vertical Resolution | 12 bit | - | - | |
Output Impedance | 50 Ω | - | - | |
DMM | ||||
Maximum Resolution | 4000 Counts | |||
DMM Testing Modes | Voltage,Current,Resistance,Capacitance,Diode &On-Off | |||
Maximum Input Voltage | AC:600V, DC: 600V | |||
Maximum Input Current | AC: 10A, DC:10A | |||
Input Impedance | 10MΩ | |||
Measurement Term | Range | Accuracy | Resolution | |
DC Voltage | 400.00mV | ± (0.8% + 5) | 100uV | |
4.000V | 1mV | |||
40.00V | 10mV | |||
400.0V | 100mV | |||
600.0V | ± (1% + 2) | 1V | ||
Overload protection: 400mV: 250V, other: 600Vrms. | ||||
AC Voltage | 4.000V | ± (1.2% + 5) | 1mV | |
40.00V | 10mV | |||
400.0V | 100mV | |||
600.0V | ±(1.5% + 5) | 1V | ||
Frequency: 40Hz~400Hz; | ||||
Frequency of 400V and 600V: 40Hz~100Hz | ||||
DC Current | 40.00mA | ± (1% + 2) | 10uA | |
200.0mA | ± (1.5% + 2) | 100uA | ||
4.000A | ± (1.8% + 2) | 1mA | ||
10.00A | ± (3% + 2) | 10mA | ||
Overload protection: | ||||
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. | ||||
AC Current | 40.00mA | ± (1.3% + 2) | 10uA | |
400.0mA | ± (1.8% + 2) | 100uA | ||
4.000A | ± (2% + 3) | 1mA | ||
10.00A | ± (3% + 5) | 10mA | ||
Frequency: 40Hz~400Hz; | ||||
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. | ||||
Resistance | 400.0Ω | ±(1% + 3) | 0.1Ω | |
4.000KΩ | ±(1.2% + 5) | 1Ω | ||
60.00KΩ | 10Ω | |||
400.0KΩ | 100Ω | |||
4.000MΩ | 1KΩ | |||
40.00MΩ | ± (1.5%±3) | 10KΩ | ||
Overload protection: 220Vrms | ||||
Capacitance | 40.00nF | ±(3% + 5) | 10pF | |
400.0nF | 100pF | |||
4.000uF | 1nF | |||
40.00uF | 10nF | |||
100.0uF | 100nF | |||
Overload protection: 220Vrms | ||||
Diode | 0V~1.0V | |||
On-Off | <50Ω | |||
General Specifications | ||||
Display | ||||
Display Type | 2.8 inch64K color TFT | |||
Display Resolution | 320 horizontal by 240 vertical pixels | |||
Display Contrast | Adjustable | |||
Power Supply | ||||
Supply Voltage | 100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A | |||
Power Consumption | <2.5W | |||
Fuse | T, 3A | |||
Battery | 2600mA*2 | |||
Environmental | ||||
Operating Temperature | 0~50 °C (32~122 °F) | |||
Storage Temperature | -40~+71 °C (-40~159.8 °F) | |||
Humidity | ≤+104℉(≤+40°C): ≤90% relative humidity | |||
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity | ||||
Cooling Method | Convection | |||
Altitude | Operating and | 3,000m (10,000 feet) | ||
Nonoperating | ||||
Mechanical Shock | Random Vibration | 0.31gRMS from 50Hz to 500Hz, 10 minutes on each axis | ||
Nonoperating | 2.46gRMS from 5Hz to 500Hz, 10 minutes on each axis | |||
Operating | 50g, 11ms, half sine | |||
Mechanical | ||||
Dimension | 199 x 98x 40mm (L x W x H) | |||
Weight | 624g | |||
Standard Accessories | Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 | Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 | Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 | Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
Model | Hantek2D72 | Hantek2D42 | Hantek2C72 | Hantek2C42 |
Oscilloscope Mode | ||||
Bandwidth | 70MHz | 40MHz | 70MHz | 40MHz |
Channel | 2CH+DMM+AWG | 2CH+DMM+AWG | 2CH+DMM | 2CH+DMM |
Horizontal | ||||
Sample Rate Range | 250MSa/s(Single-channel), 125MSa/s(Dual-channel) | |||
Waveform Interpolation | (sin x)/x | |||
Record Length | Max. 6K for single-channel; 3K samples per dual-channel | |||
SEC/DIV Range | 5ns/div~500s/div 1, 2, 5 sequence | |||
Vertical | ||||
A/D Converter | 8-bit resolution,each channel sampled simultaneously | |||
VOLTS/DIV Range | 10mV/div~10V/divat input BNC | |||
Bandwidth Limit, typical | 20MHz | |||
Low Frequency Response (-3db) | ≤10Hz at BNC | |||
Rise Time at BNC, typical | ≤5ns | |||
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div | |||
Note: Bandwidth reduced to 6MHz when using a 1X probe. | ||||
Acquisition | ||||
Acquisition Modes | Normal | |||
Trigger | ||||
Type | Edge | |||
Mode | Auto, Normal, single | |||
Level | ±4 divisions from center of screen | |||
Trigger Level Accuracy | 0.2div × volts/div within ±4 divisions from center of screen | |||
Slope | Rising, Falling, Rising & Falling | |||
Source | CH1/CH2 | |||
Input | ||||
Coupling | DC, AC or GND | |||
Input Impedance, | 25pF±3 pF, 1MΩ±2% | |||
DC coupled | ||||
Probe Attenuation | 1X, 10X | |||
Supported Probe Attenuation Factors | 1X, 10X, 100X, 1000X | |||
Maximum Input Voltage | 150VRMS | |||
Measurement | ||||
Cursor | Voltage difference between cursors: △V | |||
Time difference between cursors: △T | ||||
Automatic Measurements | Frequency, Amplitude | |||
Arbitrary Waveform Generator Mode | ||||
Waveform Frequency | Sine: 1Hz~25MHz | - | - | |
Square: 1Hz~10MHz | - | - | ||
Ramp: 1Hz~1MHz | - | - | ||
EXP: 1Hz~5MHz | - | - | ||
Sampling | 250MSa/s | - | - | |
Amplitude | 2.5Vpp(50Ω) | - | - | |
5Vpp(High impedance) | - | - | ||
Frequency Resolution | 0.10% | - | - | |
Channel | 1CH waveform output | - | - | |
Waveform Depth | 512Sa | - | - | |
Vertical Resolution | 12 bit | - | - | |
Output Impedance | 50 Ω | - | - | |
DMM | ||||
Maximum Resolution | 4000 Counts | |||
DMM Testing Modes | Voltage,Current,Resistance,Capacitance,Diode &On-Off | |||
Maximum Input Voltage | AC:600V, DC: 600V | |||
Maximum Input Current | AC: 10A, DC:10A | |||
Input Impedance | 10MΩ | |||
Measurement Term | Range | Accuracy | Resolution | |
DC Voltage | 400.00mV | ± (0.8% + 5) | 100uV | |
4.000V | 1mV | |||
40.00V | 10mV | |||
400.0V | 100mV | |||
600.0V | ± (1% + 2) | 1V | ||
Overload protection: 400mV: 250V, other: 600Vrms. | ||||
AC Voltage | 4.000V | ± (1.2% + 5) | 1mV | |
40.00V | 10mV | |||
400.0V | 100mV | |||
600.0V | ±(1.5% + 5) | 1V | ||
Frequency: 40Hz~400Hz; | ||||
Frequency of 400V and 600V: 40Hz~100Hz | ||||
DC Current | 40.00mA | ± (1% + 2) | 10uA | |
200.0mA | ± (1.5% + 2) | 100uA | ||
4.000A | ± (1.8% + 2) | 1mA | ||
10.00A | ± (3% + 2) | 10mA | ||
Overload protection: | ||||
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. | ||||
AC Current | 40.00mA | ± (1.3% + 2) | 10uA | |
400.0mA | ± (1.8% + 2) | 100uA | ||
4.000A | ± (2% + 3) | 1mA | ||
10.00A | ± (3% + 5) | 10mA | ||
Frequency: 40Hz~400Hz; | ||||
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. | ||||
Resistance | 400.0Ω | ±(1% + 3) | 0.1Ω | |
4.000KΩ | ±(1.2% + 5) | 1Ω | ||
60.00KΩ | 10Ω | |||
400.0KΩ | 100Ω | |||
4.000MΩ | 1KΩ | |||
40.00MΩ | ± (1.5%±3) | 10KΩ | ||
Overload protection: 220Vrms | ||||
Capacitance | 40.00nF | ±(3% + 5) | 10pF | |
400.0nF | 100pF | |||
4.000uF | 1nF | |||
40.00uF | 10nF | |||
100.0uF | 100nF | |||
Overload protection: 220Vrms | ||||
Diode | 0V~1.0V | |||
On-Off | <50Ω | |||
General Specifications | ||||
Display | ||||
Display Type | 2.8 inch64K color TFT | |||
Display Resolution | 320 horizontal by 240 vertical pixels | |||
Display Contrast | Adjustable | |||
Power Supply | ||||
Supply Voltage | 100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A | |||
Power Consumption | <2.5W | |||
Fuse | T, 3A | |||
Battery | 2600mA*2 | |||
Environmental | ||||
Operating Temperature | 0~50 °C (32~122 °F) | |||
Storage Temperature | -40~+71 °C (-40~159.8 °F) | |||
Humidity | ≤+104℉(≤+40°C): ≤90% relative humidity | |||
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity | ||||
Cooling Method | Convection | |||
Altitude | Operating and | 3,000m (10,000 feet) | ||
Nonoperating | ||||
Mechanical Shock | Random Vibration | 0.31gRMS from 50Hz to 500Hz, 10 minutes on each axis | ||
Nonoperating | 2.46gRMS from 5Hz to 500Hz, 10 minutes on each axis | |||
Operating | 50g, 11ms, half sine | |||
Mechanical | ||||
Dimension | 199 x 98x 40mm (L x W x H) | |||
Weight | 624g | |||
Standard Accessories | Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 | Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 | Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 | Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
Select | Model | Bandwidth | Channels | Sampling rate | Other |
---|---|---|---|---|---|
![]() TO1000 Series
|
110MHz 150MHz 200MHz 250MHz |
2/4CH(DSO) 1CH(AFG) DMM |
1GSa/s 250MSa/s |
DSO/DMM/AFG/FFT Light weight and is easy to carry Support fast charging, and abundant power |
|
![]() Hantek2000 Series
|
70MHz 40MHz |
2CH(DSO) 1CH(AFG) DMM |
250MSa/s | DSO/DMM/AFG Volume small, one hand holding Type C charging,Ultra-low power design Powerful PC software,with recorder function |
|
![]() DSO8000E Series
|
70-200 MHz(DSO) 25MHz(AFG) |
2CH(DSO) 1CH(AFG) |
1GSa/s(DSO) 200MS/s(AFG) |
DSO/DMM/AFG/Frequency Counter/Spectral analysis/Recorder IP-51 rated for dust, drip and shake proof, Anti-theft lock/Flash Light/ Tripod fixed hole/2M memory, |
|
![]() DSO1000E Series
|
70-200MHz | 2CH | 1GSa/s | DSO/DMM/ Frequency Counter/ Spectral analysis/Recorder IP-51 rated for dust, drip and shake proof Anti-theft lock/Flash Light/ Tripod fixed hole/2M memory, |
|
![]() DSO1000S Series
|
60/120/150/200MHz | 2CH | 1GSa/s | 6000 Counts DMM High Resolution(640*480), 1M memory depth. |
|
![]() DSO8060 Series(Discontinued)
|
60MHz | 2CH | 250MSa/s | DSO/DMM/ Frequency/ Spectral analysis/6000 Counts DMM |
|
![]() DSO1000 Series(Discontinued)
|
200MHz/60MHz | 2CH | 500MSa/s 250MSa/s |
6000 Counts DMM Resolution(320*240) 32K memory depth |
|
![]() DSO1000B Series(Discontinued)
|
60MHz-200MHz | 2CH | 1GSa/s | 6000 Counts DMM High Resolution(640*480), 1M memory depth. |
|
![]() DSO1000BV Series (Discontinued)
|
60MHz-200MHz | 2CH | 1GSa/s | 6000 Counts DMM High Resolution(640*480), 1M memory depth. Video auxiliary function |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Model | Description | View Manual |
HT300B,HT500B | 350Mhz,500MHz,10:1/1:1 | Download |
HT-100B,HT-200B | 100MHz,200MHz,10:1/1:1 | Download |
PP-80,PP-150,PP-200 | 60MHz,100MHz,200MHz,10:1/1:1 | Download |
PP80B, PP150B, PP200B, PP300B | 80Mhz, 150MHz, 200MHz, 300MHz, 10:1/1:1 | Download |
PP-90 | 80MHz,10:1/1:1 | Download |
T3100 | 100MHz,100:1,2000VDC Peak AC | Download |
Model | Description | View Manual |
CC65 | AC/DC: 0 – 20KHz,20mA to 65A DC | Download |
CC650 | AC:0 – 5KHz,1A - 500A ,DC:1A - 650A | Download |
CC800 | AC:0 – 5KHz,1A - 500A ,DC:1A - 800A | Download |